Alarm mode
The condition monitor enters alarm mode when either vibration or temperature limits are
exceeded over two consecutive readings within a ten minute period. Alarm mode is indicated
with two red flashing LEDs within two second intervals.
Temperature and vibration limits
Variable
Limit
Temperature
195°F (91°C)
Vibration
100% increase over the baseline level
Battery life
The i-ALERT Condition Monitor battery is not replaceable. You must replace the entire unit
once the battery runs out of power.
The battery life is not covered as part of the standard five-year pump warranty.
This table shows the average condition monitor battery life under normal and alarm-mode operating
conditions.
Condition monitor operational state
Battery life
Normal operating and environmental conditions
Three to five years
Alarm mode
One year
Nameplate information
Important information for ordering
Every pump has nameplates that provide information about the pump. The nameplates are
located on the casing and the bearing frame.
When you order spare parts, identify this pump information:
• Model
• Size
• Serial number
• Item numbers of the required parts
Refer to the nameplate on the pump casing for most of the information. See Parts List for item
numbers.
Nameplate types
Nameplate
Description
Pump casing
Provides information about the hydraulic characteristics of the pump.
The formula for the pump size is: Discharge x Suction - Nominal Maximum Impeller
Diameter in inches.
(Example: 2x3-8)
Bearing frame
Provides information about the lubrication system used.
ATEX
If applicable, your pump unit might have an ATEX nameplate affixed to the pump, the
baseplate, or the discharge head. The nameplate provides information about the
ATEX specifications of this pump.
IECEx
If applicable, your pump unit might have the following IECEx nameplate affixed to the
pump and/or baseplate. The nameplate provides information about the IECEx
specifications of this pump.
16