Discharge piping checklist – Goulds Pumps 3196 i-FRAME - IOM User Manual
Page 40

Installation
Example: Suction piping equipment
Correct
Incorrect
1. Suction pipe sloping upwards from liquid
1. Air pocket, because the eccentric reducer
source
is not used and because the suction piping
2. Long-radius elbow
does not slope gradually upward from the
3. Strainer
liquid source
4. Foot valve
5. Eccentric reducer with a level top
Discharge piping checklist
Checklist
Check
Explanation/comment
Checked
Check that an isolation valve is
The isolation valve is required for:
installed in the discharge line.
• Priming
• Regulation of flow
• Inspection and maintenance of the pump
See Example: Discharge piping equipment for
illustrations.
Check that a check valve is in-
The location between the isolation valve and
stalled in the discharge line, be-
the pump allows inspection of the check valve.
tween the isolation valve and the
The check valve prevents damage to the
pump discharge outlet.
pump and seal due to the back flow through
the pump, when the drive unit is shut off. It is
also used to restrain the liquid flow.
See Example: Discharge piping equipment for
illustrations.
If increasers are used, check that
See Example: Discharge piping equipment for
they are installed between the
illustrations.
pump and the check valve.
If quick-closing valves are installed This protects the pump from surges and water
in the system, check that cushion- hammer.
ing devices are used.
38
Model 3196 i-FRAME Installation, Operation, and Maintenance Manual