2 long term – Pulsafeeder Polyfeeder EN User Manual
Page 8

8
d) If required by the operating environment, take precautions to prevent entry of water, humid air,
or chemical vapors into the system and control enclosures.
e) Prior to startup, perform a complete inspection and then start up in accordance with instructions
in this manual.
5.2 Long
Term
After twelve months of storage, Pulsafeeder’s warranty cannot cover items that are subject to deterioration
with age, such as seals, gaskets, and diaphragms. If the system has been in storage longer than 12 months
it is recommended that these items be inspected and replaced as necessary prior to startup. Materials and
labor to replace this class of item under this circumstance are the purchaser’s responsibility. Consult your
local Pulsafeeder representative for assistance in obtaining parts and service for your PolyFeeder system.