agb220xa_biasChanList_Q
This function will query the instrument for the status, bias enabled or bias disabled, 
for the channels given in the list.
The parameter “biaschan_list” is an array of integers with each integer representing 
one channel. The last number of the “biaschan_list” should be “0” (numeric zero) to 
identify the end of the list. The maximum number of channels that can be specified 
by the list is 100.
The “bias_status” parameter is an array of integers containing the return values of 
the query. The “bias_status” array returned will correspond one to one with 
“biaschan_list” parameter. 
Syntax
ViStatus _VI_FUNC agb220xa_biasChanList_Q(ViSession vi, ViInt16 bias_disen, 
ViInt32_VI_FAR biaschan_list[ ], ViInt32_VI_FAR bias_status[ ] );
Parameters
vi
Instrument handle returned from agb220xa_init( ).
bias_disen
Query type.
0 : checks if the port is the bias enabled.
1 : checks if the port is the bias disabled.
biaschan_list[ ]
Channel numbers to check the status. 5 digits integer. ABCDE. 
where A: card number, BC: input port number, DE: output port 
number. Top zero(s) can be ignored. For example, if A=0, 
BC=01, and DE=01, channel number should be 101 instead of 
00101.
bias_status[ ]
Status of the channels given in the biaschan_list. Returned 
value depends on the setting of bias_disen as shown below:
when bias_disen=0, 0 means bias disabled, 1 means enabled.