beautypg.com

Transport storage – Karcher SB Wash Oel 50-10 F VA User Manual

Page 24

background image

-

10

Caution
Risk of injury and damage! Observe the
weight of the appliance when you transport
it.

When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.

Caution
Risk of injury and damage! Note the weight
of the appliance in case of storage.

Pump does not
start

Buffer tank for permeate is full

Wait until the permeate is consumed.

Operator

Level switch Buffer tank is full is defective Check level switch.

Customer
Service

Start-up time of the control has not yet
been completed

Wait. Operator

Pressure switch for water scarcity is defec-
tive

Check pressure switch; replace it, if required.

Customer
Service

Regeneration of the base exchanger is
running

Wait for regeneration to end.

Operator

No softened water is coming from the base
exchanger

Check the base exchanger.

Operator/
Customer
Service

Pump continu-
ously goes on
and off

Finest filter or active carbon filter is dirty

Check filter; replace the filter inlay, if required

Operator

Regeneration of the base exchanger is in-
complete

Add salt, add water and wait for brine formation (ap-
prox. 2 hours); start regeneration, check the base ex-
changer, if required.

Operator/
Customer
Service

Pump starts only
after several rins-
ing cycles

Too low mains water pressure

Check mains water supply; open the inlet valve fully,
if required.

Operator

Finest filter or active carbon filter is dirty

Check filter; replace the filter inlay, if required

Customer
Service

Permeate output
is too low; buffer
tank of permeate
is often empty

Water inlet temperature is too low

Measure the temperature of the softened water and
compare it with the technical data.

Operator

Operating pressure is too low

Reset the operating pressure.

Customer
Service

There are calcium or mineral deposits on
the filter surface of the RO membrane.

Decalcify the membrane; replace it, if necessary

Customer
Service

Level switch Buffer tank is "full" is defec-
tive

Check level switch.

Customer
Service

There are bacteria or algae deposits on
the filter surface of the RO membrane.

Rinse the membrane thoroughly for a long time; re-
place it if necessary. In future remember: Water is of
potable quality; avoid long idling periods.

Customer
Service

There are stains
on the car paint
during Top Care
(permeate has
not been ade-
quately deminer-
alised)

The mineral content of the softened water
is too high

Check conductivity of softened water.

Customer
Service

RO membrane has ruptured; defective
sealing

Replace washer or membrane. Check conductivity

Customer
Service

Mixing of permeate and softened water

Comparison of conductivity of the permeate from the
spray pipe and water from the buffer tank of perme-
ate.

Customer
Service

Transport

Storage

24