6

Caution
Wear a grounding device and observe all electrostatic discharge
precautions when installing the AT-MCM02 Management Module in the
media converter. Failure to observe this precaution could result in
damage to the unit.

4.

Align the AT-MCM02 Management Module with the card guides on the
bottom on the media converter and gently slide the module into place.
Refer to Figure 2.

When the module is about 5 millimeters (0.20 inches) from the media
converter’s backplane, you will feel a slight resistance. At that point, make
sure that the edges of the AT-MCM02 Management Module are parallel to
the corresponding edges of the media converter. Continue to slide the
management module, applying slight pressure, to seat the management
module’s connectors into the media converter’s backplane.

Figure 2 Installing the AT-MCM02 Module

5.

Secure the mangement module to the media converter by tightening the
two thumbscrews.

6.

Apply power to the media converter by connecting the AC power cord or
DC wires. Refer to installation guide that came with the media converter
for instructions.

7.

Check to be sure that the Power LED(s) on the front of the media
converter are green. If the LED(s) are OFF, refer to “Troubleshooting” on
page 27
.

8.

Check the Ready LED on the front panel of the media converter. The LED
should be green. If the LED is OFF, refer to “Troubleshooting” on page 27.

9.

The management module is now ready to be configured. Proceed to
Chapter 3 for instructions on how to configure the management module.

Mana

gement

Port

>

Power Suppl

y

<

Main

<<

Back-Up

AC LINE
100-240 V

AC

50-60 Hz
1.5A MAX

50 W

AT-MCM02

Mana

gement

Port

>