AT-MCM02 Management Module Installation Guide

5

Installing the Management Module

To install the management module in your multichannel media converter,
perform the following procedure:

Warning
Installing the AT-MCM02 Management Module while the media
converter is powered ON could result in damage to the module.

1.

Power OFF the media converter by performing one of the following:

For an AC model, unplug the power cord from the power outlet and
then unplug the power cord from the media converter.

For a DC model, follow the steps below:

Warning
When installing this equipment, alway ensure that the frame ground
connection is installed first and disconnected last.

$ 15

a. Remove the positive and negative feed wires from the terminal block

by loosening the screws to the wire connections with a flathead
screwdriver.

b. Remove the frame ground wire from the terminal block by loosening

the screw to the wire connection with a flathead screwdriver.

2.

Using a Phillips-head screwdriver, remove the blank faceplate from the
management module expansion slot, located on the back panel of the
media converter. See Figure 1.

Figure 1 Removing the Blank Faceplate

3.

Remove the management module from the package and store the
packaging in a safe place.

Mana

gement

Port

>

Power Suppl

y

<

Main

<<

Back-Up

AC LINE
100-240 V

AC

50-60 Hz
1.5A MAX

50 W