1 checkbox column, 2 mib variable column, 3 mib value column – Allied Telesis AT-VIEW PLUS 3.2 DEVICE MANAGER User Manual
Page 73: 4 select all button, 5 clear button, 6 reverse button, 7 get mib value button, 6 reverse button 6.4.7 get mib value button, Checkbox column, Mib variable column
Allied Telesyn
AT-VIEW PLUS
DEVICE MANAGER
6.4.1 Checkbox Column
The first (leftmost) column shows whether or not the variable can be changed (i.e. the variable
supports the SNMP Set operation). If a checkbox is displayed in the column, the variable's value
can be changed.
When you change several variables, set the new values in the Value column and then check all
corresponding boxes. AT-View Plus Device Manager sends new values for selected variables in
a batch.
6.4.2 MIB Variable Column
MIB variable names are displayed.
6.4.3 MIB Value Column
The value of the variable is displayed. If the variable has write access (and a checkbox is
displayed in the first column), this field is editable. To change the MIB value, change the value
and check the box and then click the Set MIB Value button. If the variable takes a value from a
fixed set of options, this field works as a pull down listbox. For such a variable, clicking this field
shows the listbox.
The value in this field is the one at the time when this tab is opened. The value in this column is
not updated automatically. If you want to see the latest value, use the Get MIB Value button or
switch to the Table tab.
Note
- SNMPv3: Depending on the READ VIEW access settings of the User Account Name
used, there is a possibility that AT-View Plus Device Manager may not be able to access some
MIB values. When this happens, the table will display a blank cell for those MIB values.
6.4.4 Select All Button
: checks all variables that can be changed.
6.4.5 Clear Button
: unchecks all variables that can be changed.
6.4.6 Reverse Button
: Flips the states of all checkboxes, that is, unchecks all variables currently checked, and
checks all variables currently not checked.
6.4.7 Get MIB Value Button
: Updates the MIB Value fields of the selected variables. To select a variable, click the MIB
Variable field of the target variable.
PN 613-50664-00 Rev C