$CURRENT

Current value of the variable.


$MAXVALUE

Highest value of the variable during the monitoring period.


$MINVALUE

Lowest value of the variable during the monitoring period.


$AVERAGE

Average value of the variable during the monitoring period.


$MAXLIMIT

Threshold value configured for the variable.

For trap events

$TRAPHOST

The host name of the device which sent the trap.


$TRAPIPADDR

The IP address of the device which sent the trap.


$GENERICTRAP

The generic trap number.


$SPECIFICTRAP

The specific trap number.


$ENTERPRISEOID

The trap's enterprise OID.


$ENTERPRISENAME

The name of the Trap MIB object. If AT-View Plus Device Manager cannot get
an object name, $ENTERPRISEOID is used instead.


$TIMETICKS

The trap's TIMETICKS.


$VAROIDn

The OID of the n

th

MIB object sent with the trap, where n is a number in the range

1 to 9.