3 regist menu, 4 save polling data, Regist menu – Allied Telesis AT-VIEW PLUS 3.2 DEVICE MANAGER User Manual
Page 105: Save polling data

Allied Telesyn
AT-VIEW PLUS
DEVICE MANAGER
Data sampled by RMON Data displayed by AT-View Plus
Device Manager
Sample 1 100 100
Sample 2 50 150
Sample 3 250 400
Per Sample
Displays data which AT-View Plus Device Manager got from the RMON agent as it is.
Data sampled by RMON
Data displayed by AT-View Plus
Device
Manager
Sample 1 100
100
Sample 2 50
50
Sample 3 250
250
Per Second
Displays "Sampled data / Sampling Interval configured on the RMON agent". The
sampling interval here is the RMON agent's sampling interval, not the interval configured
in AT-View Plus Device Manager. In the following example, the RMON agent's
sampling interval is 10 seconds.
Note
- Calculated values are rounded. For example, the Number of Error packets is
usually very small so that the calculated value is likely to be zero.
Data sampled by RMON Data displayed by AT-View Plus
Device
Manager
Sample 1 100 10 (100 / 10)
Sample 2 50 5 (50 / 10)
Sample 3 250 25 (250 / 10)
7.3.7.3 Regist Menu
Add this window to the user-defined User Menu.
7.3.7.4 Save Polling Data
This button opens the Polling Data Save dialog box, used to save collected data to a file. Specify
the name and format of the file in which the data is to be saved. Select a file format from the
options below. To start saving the data, click OK.
When you start saving data, the button's label changes to "Saving polled data". To close the file
and stop saving the data, click the "Saving polled data" button.
CSV Format
Saves the data in comma-separated values (CSV) format.
TAB Format
Saves the data in tab-separated values (TSV) format.
Note
- Only the values of the collected RMON variables are saved. Values AT-View Plus Device
Manager calculates from these collected values are not saved.
PN 613-50664-00 Rev C
Page 105 of 119