1 alarm table tab, Alarm table tab – Allied Telesis AT-VIEW PLUS 3.2 DEVICE MANAGER User Manual
Page 109

Allied Telesyn
AT-VIEW PLUS
DEVICE MANAGER
7.4.1 Alarm Table Tab
The Alarm Table shows the list of currently defined alarm entries.
Index
The index number used to identify this alarm entry.
Sampling Interval
The time interval at which the RMON agent samples data.
Sampling MIB Variable Name
MIB variable to be monitored. The object type must be one of INTEGER, COUNTER,
GAUGE and TIMETICKS.
Sampling Type
How to compare the sampled value with the threshold. "absolute value" means comparing
the sampled data with the threshold without modification. "delta value" means comparing
the difference between the latest sampled value and the previous sampled value with the
threshold.
Sampling Value
The last sampled value.
Startup Alarm Type
The type of threshold which is applied to the first sampled value after this Alarm entry
becomes valid.
rising alarm
A single RMON event is triggered if the first sampled value is greater than or
equal to the configured rising threshold.
falling alarm
A single RMON event is triggered if the first sampled value is less than or equal
to the configured falling threshold.
rising or falling alarm
A single RMON event is triggered if the first sampled value is greater than or
equal to the configured rising threshold, or if the first sampled value is less than or
equal to the configured falling threshold.
Rising Threshold
The ceiling threshold.
Falling Threshold
The floor threshold.
Rising Event Index
The index of the RMON Event entry which is triggered when the sampled value rises
above the rising threshold.
PN 613-50664-00 Rev C
Page 109 of 119