4 edit button, 5 remove button, 6 close – Allied Telesis AT-VIEW PLUS 3.2 DEVICE MANAGER User Manual
Page 113: 5 remove button 7.4.6 close, Edit button, Remove button, Close
Allied Telesyn
AT-VIEW PLUS
DEVICE MANAGER
Event Description
Text string describing the event. By default, "Rising Event for Alarm#idx" is used
where "idx" represents the Alarm index number.
Falling Alarm Event Rule
Configuration for the falling alarm. If you select "rising alarm" for the Startup Alarm
Type, only "Falling Threshold" and "Falling Event Index" can be configured. If there is
no Event entry corresponding to the Event Index, no event will occur.
Falling Threshold
The floor threshold. If the monitored variable falls below this threshold, a falling
alarm event occurs. The default is 2000.
Event Type
The type of action to be taken when the event occurs. Select one of "none" (no
action
taken), "SNMP trap" (send an SNMP trap), "log" (record to the log) and "log &
SNMP trap" (record to the log and send an SNMP trap).
Falling Event Index
The index of the RMON Event entry which is triggered when the sampled value
falls below the falling threshold. If you select "rising alarm" for the Start Alarm
Type, this defaults to zero. Because an Event Index of 0 is invalid and there is no
event related to Index 0, no event will occur even if falling alarm is triggered.
TRAP Community
Trap Community name.
Event Description
Text string describing the event. By default, "Falling Event for Alarm#idx" is used
where "idx" represents the Alarm index number.
7.4.4 Edit Button
: edits the selected Alarm entry. Click this button to open a dialog box, specify options, then
click OK. You can also open this dialog box by double-clicking the entry.
7.4.5 Remove Button
: removes the selected Alarm entry.
7.4.6 Close
Closes the window.
7 RMON
PN 613-50664-00 Rev C
Page 113 of 119