Polling Options dialog box

Polling Interval

AT-View Plus Device Manager sends a GetRequest to the SNMP agent at
predefined polling intervals to ensure that it is still connected to the device. If a
shorter or longer interval is required adjust the value in the Polling Interval field
accordingly.

The minimum interval is 5 seconds and the maximum is 3600 seconds (1 hour).
The default is 30 seconds.


Retry

Configures the SNMP timeout and the number of retries.


Timeout

The number of seconds AT-View Plus Device Manager waits before it determines
that the device is not responding. The default is 5 seconds.


Retry times

The number of times AT-View Plus Device Manager sends SNMP messages to
the agent before giving up. The default is 2 retries.


Enable periodic device polling

To regularly check the hardware configuration of hot-swappable devices, check
this box. When this is checked, AT-View Plus Device Manager checks the
hardware configuration at every polling interval. The Panel window shows any
hardware configuration changes it finds.

If the target device is not hot-swappable, or if you do not expect any hardware
configuration changes, do not check this box. Polling the hardware configuration
may reduce performance.

Note

- AT-View Plus Device Manager always checks the latest hardware

configuration of the target device when initiating connection. To check the
configuration on demand after the session is established, select View > Refresh.