beautypg.com

Starting a local management session, Data bits: 8, Parity: none – Allied Telesis AT-LX3800U User Manual

Page 66: Stop bits: 1, Flow control: none, Chapter 2: installation 66

background image

Chapter 2: Installation

66

Starting a Local Management Session

The procedure in this section explains how to start a local (out-of-band)
management session using the RS-232 terminal port on the chassis. You
can use a local management session to configure the chassis operating
parameters and view system status using the AT-S65 management
software.

Note

Only one manager can log in at a time.

To start a local management session, perform the following procedure:

1. Connect the DIN-8 end of the management cable included with the

AT-LX3800U chassis to the RS-232 terminal port on the front of the
chassis, as shown in Figure 43.

Figure 43. Connecting the Local Management Cable to the Terminal Port

2. Connect the other end of the cable to an RS-232 port on a terminal or

PC with a terminal emulation program.

3. Configure the terminal or terminal emulation program to the following

settings:

ˆ

Baud rate: 115200 bps

ˆ

Data bits: 8

ˆ

Parity: None

ˆ

Stop bits: 1

ˆ

Flow control: None

TX

CLASS 1

LASER PRODUCT

10/100Base-TX

RS-232

TERMINAL

FT

CO

PA

PB

8

RESET

AT-LX3800U

8

LINE

C

LINE

AT-LX3811/8

SFP

SYNC

TX

RX

LINE

RDY

TX

RX

TRIB

RX

100 10

154

154