Note
A pass-through optical power monitor is required because when the
fiber optic cable is removed from the RX or TX port, the Open Fiber
Control algorithm is activated. This results in a significant reduction
in optical power compared to the closed loop actual optical power
value.
If the received optical power is greater than -7 dBm per channel,
additional attenuation is required. RX values greater than -7 dBm per
channel could potentially damage the optical receiver if applied for
more than 60 seconds.
Note
When you add attenuation to the system, ensure that the attenuated
value does not drop below the receiver’s sensitivity values. Refer to
“Optical Specifications” on page 76 for more information.
3. Remove the pass-through optical power monitor from the RX port.
4. Connect the appropriate fiber optic cable to the TX and RX line ports,
as shown in Figure 34.