Property Name Description
Valid Values
•
any
This can also be set by entering
an integer from 0-255.
Source IP
Address
Specifies the source IP address
(either host or subnet) of an IP
packet.
This can be set by entering an
IPV4 or IPV6 address using the
following format:
•
IPv4 address[/mask] -
IPv4 is in dotted decimal
notation, mask is 0..32.
•
IPv6 address[/mask] -
IPv6 is in colon separated
hex digit notation, mask
is 0..128.
This value can also be set
to "any".
Destination IP
Address
Specifies the destination IP
address (either host or subnet)
of an IP packet.
This can be set by entering an
IPV4 or IPV6 address using the
following format:
•
IPv4 address[/mask] -
IPv4 is in dotted decimal
notation, mask is 0..32.
•
IPv6 address[/mask] -
IPv6 is in colon separated
hex digit notation, mask
is 0..128.
This value can also be set
to "any".
Destination
IPX Address
Specifies the destination
network address of an IPX
packet.
This can be set by entering an 8
digit hexadecimal value.
(00000001-FFFFFFFF)
This can also be set to "any".
Source IPX
Socket
Specifies the source IPX socket
number of an IPX packet.
This can be set by entering a 4-
byte hexadecimal value (0000-
FFFF) or by selecting one of the
following:
•
NCP
•
SAP
•
RIP
•
NNB
AlliedView™-EMS 3.10 QoS Manager User’s Guide