2 flow groups, 1 qos information window, 1 add/modify flow group – Allied Telesis AlliedView-EMS 3.10 QoS MANAGER User Manual
Page 113: Flow groups

Property Name Description
Valid Values
to be checked.
Match2
Specifies the actual data to
match
This can be set by entering a 4-
byte hex number. (0000-FFFF)
Mask2
Specifies whether the
corresponding bit in the
Match2 parameter is "on" for a
match or "don't care" for a
match.
This can be set by entering a 4-
byte hex number. (0000-FFFF)
Offset2
Specifies the location or offset
where the pattern for Match2 is
to be checked.
Range: 0-62
Match3
Specifies the actual data to
match
This can be set by entering a 4-
byte hex number. (0000-FFFF)
Mask3
Specifies whether the
corresponding bit in the
Match3 parameter is "on" for a
match or "don't care" for a
match.
This can be set by entering a 4-
byte hex number. (0000-FFFF)
Offset3
Specifies the location or offset
where the pattern for Match3 is
to be checked.
Range: 0-62
6.8.2 Flow Groups
6.8.2.1 QoS Information Window
Column Name
Description
Flow Group ID
Lists the ID of Flow Groups available
Description
A brief description of the Flow Group.
Classifiers
List of Classifiers associated with this Flow
Group
6.8.2.1 Add/Modify Flow Group
Property Name Description
Valid Values
Flow Group ID
(cannot be
modified)
Specifies the unique identifier
for the Flow Group.
Range: 0-1023
Description
Specifies a brief description of
the Flow Group.
To set this value, enter an
alphanumeric string from 1-15
characters.
Mark Value
This parameter specifies a
replacement value to write into
the DSCP (TOS) field for all
packets.
Range: none, 0-63
AlliedView™-EMS 3.10 QoS Manager User’s Guide
Page 113 of 128