IX5-28GPX Installation Guide

63

Installing Power Supply Modules

Overview

The AT-IX5-28GPX switch has two rear slots for hot-swappable power
supplies. You can install one or two AT-PWR800 power supplies.

The switch is supplied with a factory installed blank panel that covers both
power supply slots, and with a separate blank panel to use if you only
install one power supply.

The installation procedure is identical for each power supply.

Installing a

Power Supply

To install a power supply, perform the following procedure:

1. Remove the module from the shipping package.

Note

Store the packaging material in a safe location. You must use the
original shipping material if you need to return the unit to Allied
Telesis.

2. Remove the blank panel from the power supply slots on the rear panel

of the switch by unscrewing it, as shown in the following figure.

Figure 19. Removing the rear panel