beautypg.com

H4tu-c-319 card-edge connector, Network management control bus, Fuse alarm – ADC HDSL4 User Manual

Page 70: H4tu-c-319 card-edg, H4tu-c-319, H4tu-c-319 c, Onnector

background image

Appendix A - Specifications

LTPH-UM-1031-03, Issue 3

62

September 12, 2003

H4TU-C-319 List 1

H4TU-C-319 C

ARD

-E

DGE

C

ONNECTOR

Figure 32

shows the card-edge connectors on the H4TU-C-319. Active pins are highlighted in black.

Figure 32.

H4TU-C-319 Card-Edge Connector

Network Management Control Bus

The H4TU-C provides a Network Management Control Bus on pin 7 of the card-edge connector. This allows the
various Management System protocols to manage the H4TU-C through the HMU-319. Whenever the H4TU-C is
under management, the

MNGD

message displays periodically on the front-panel display.

Fuse Alarm

Pin 10 on the card-edge connector is a Fuse Alarm that is driven to -48 Vdc whenever its onboard fuse opens. It
emulates the function of the Fuse Alarm output from pin 10 on normal, high-density (HD) repeaters. Pin 10 is
connected to pin 5 of the 1184 Alarm Card (slot 1 in the HD shelf) and causes the 1184 Fuse ALM LED to light
when the pin 10 signal is activated. Its normally floating output must never be driven above ground or below
-80 V. It can sink a current of 10 mA. The H4TU-C does not support the BPV function (Pin E) of normal HD
repeaters.

Some H4TU-C-319 features are affected when it is under management. Consult the management
unit practice for further information (see

“Appendix D - Product Support” on page 66

).

3

4

5

6

C

D

E

F

H

7

8

J

9

K

10

L

GND

HDSL4 - L1Tip

HDSL4 - L1 Ring

System Alarm**

Management Bus**

Frame GND

-48 Vdc

Fuse Alarm*

(Do not use)

1

A

(IN) DSX-1Tip

DSX-1 Ring (IN)

2

B

(OUT) DSX-1Tip 1

DSX-1 Ring 1 (OUT)

Fuse Alarm

System Alarm and Management Bus (reserved)

Normal = Floating (0 to -60 Vdc maximum)
Activated = -48 Vdc (10 mA maximum)

*

**

HDSL4 - L2Tip

HDSL4 - L2 Ring

This manual is related to the following products: