H4tu-r ds1 alarm history screen, Ds1 alarm descriptions, 1 interfaces – ADC HDSL4 User Manual

Page 44: Figure 23 on

background image

Monitoring System Activity and Performance

LTPH-UM-1031-03, Issue 3

36

September 12, 2003

H4TU-C-319 List 1

Figure 23.

H4TU-R DS1 Alarm History Screen

Table 11.

DS1 Alarm Descriptions

Screen Alarm

Front-Panel
Alarm

Description

H4TU-C DS1 Alarms (

Figure 22 on page 35

)

LLOS

(a)

(a) This is a DS1-specific alarm that also issues a minor alarm (sent to the management unit or the backplane), if enabled.

LLOS

Line (Unit) Loss of Signal—Loss of the H4TU-C DSX-1 input signal.

LAIS

(a)

LAIS

Line Alarm Indication Signal—Indicates an AIS (unframed all ones) pattern is being received at the
H4TU-C DS1 input port.

DBER

xxx-DBER

Bit Error Rate—The DS1 BER has exceeded the built-in 24-hour threshold limits of approximately
10

-6

. (xxx denotes either TUC or TUR.)

LOF

xxx-LOF

Loss of Frame—Indicates the incoming DS1 frame pattern is other than the one selected, ESF or SF,
by the FRMG option. Only occurs if the FRMG option is set to SF or ESF. (xxx denotes either TUC or
TUR.)

H4TU-R DS1 Alarms (

Figure 23

on this page)

RLOS

(b)

(b) AIS-CI is a modified AIS alarm pattern. Equipment not suited to detect AIS-CI still detects this signal as an AIS. AIS-CI is sent

toward the network indicating that an LOS (RLOS) or AIS (RAIS) has been received from the CPE.

RLOS

Remote (Unit) Loss of Signal—Loss of the H4TU-R DS1 input signal.

RAIS

RAIS

Remote Alarm Indication Signal—Indicates an AIS (unframed all ones) pattern is being received at the
H4TU-R DS1 input port. By default AIS-CI

(b)

is sent towards the network (see

Figure 27 on page 45

)

RAI

RRAI

Remote RAI - Remote Alarm Indication at the H4TU-R—Indicates an RAI alarm (yellow) from the CPE
with errors from the line unit or network.

LRAI

LRAI

Line (Clear) Remote Alarm Indication—An RAI condition is detected at the remote and the signal from
the line unit is error-free. RAI signal is transmitted towards the network.

PRM-NE

PRMN

Performance Report Messaging - Near End—The count of the PRM-NE register at the H4TU-R
exceeds the 10

-6

BER threshold at 648 events since 12:00:00 AM.

PRM-FE

PRMF

Performance Report Messaging - Far End—The count of the PRM-FE register at the H4TU-R exceeds
the 10

-6

BER threshold at 648 events since 12:00:00 AM.

DBER

xxx-DBER

Bit Error Rate—The DS1 BER has exceeded the built-in 24-hour threshold limits of approximately
10

-6

. (xxx denotes either TUC or TUR.)

LOF

xxx-LOF

Loss of Frame—Indicates the incoming DS1 payload does not contain the specific frame pattern, ESF
or SF, selected by the FRMG option. Only occurs if the FRMG option is set to SF or ESF. (xxx denotes
either TUC or TUR.)

Monitor

Performance

Event Log Config Inventory Report Rlogon Help

H4TU-R DS1 Alarm History
-----------------------------------------------------------------------------

Alarm First Last Status Count

RLOS OK 0
RAIS OK 0
RAI OK 0
LRAI OK 0
PRM-NE OK 0
PRM-FE OK 0

DBER 01/30/02 00:37 01/30/02 00:45 OK 7
LOF OK 0

Press: C(l)ear Alarm History
------------------------------------------------------------------------------

Use to cycle through

Interface : H4TU-R DS1

choices and to view

Statistics :

Alarm History

ID: xxxx--xxxx--xxxx--xxxx 02/01/2002 12:30:01 H4TU-C System: Alarm