LTPH-UM-1031-03, Issue 3

Testing

H4TU-C-319 List 1

September 12, 2003

57

T

ESTING

WITH

H4TU-R BERT G

ENERATOR

The H4TU-R BERT Generator screen allows transmission of an unframed test signal from the H4TU-R towards
either the network (NET) or customer (CPE). Bit error rates are calculated and display on the Monitor screen.

1

Press

to logon remotely, then press

to select the Config menu (

Figure 31

).

2

Use the

and

arrow keys to select BERT Generator, then press

.

3

Use the arrow keys to select an option, then press the

to cycle through the settings. Refer to

Table 19 on page 56

for a list of BERT Generator option settings.

4

Press

to activate your choice.

5

To view BERT status, press

twice, then, using the

arrow key to select the Monitor menu, press

.

6

Press

to return to the H4TU-C logon screen. You can exit the status screen while signal generation is active.

Figure 31.

H4TU-R BERT Generator Screen

The test pattern is sent out either from the line unit towards the network (toward NET) or from
the remote unit towards the customer (toward CPE). Both test payloads must be looped back so
they can be returned to the unit for BER detection. BER detection is performed in the line unit
for both switch settings.

Tests done towards the NET must be looped at some point external to the higher circuit. Tests
done towards the CPE can either be looped back at some external point beyond the remote unit,
or they can be looped back internally by a higher loopback, such as NREM. The test payload,
for the CPE direction, also passes back and forth over the HDSL4 link to the H4TU-C before it is
analyzed for errors.

R

C

ENTER

SPACEBAR

ENTER

ESC

ENTER

R

Monitor Performance Event Log

Config

Inventory Report Rlogon Help

+----------------------+
| Standard Options -> |
| ADC Options -> |
|

BERT Generator ->

|

+--------------------------------------+
| BERT Signal Generator :

ENA

|

| BERT Signal Pattern : 1 in 8 |
| BERT Signal Linecode : AMI |
| BERT Signal Direction : NET only |
| BERT Interval : Continuous |
+--------------------------------------+

Use to cycle through option settings and to activate
ID: xxxx—-xxxx—-xxxx--xxxx 02/01/2002 12:30:01 H4TU-R System: OK