beautypg.com

ADC HDSL4 User Manual

Page 63

background image

LTPH-UM-1031-03, Issue 3

Testing

H4TU-C-319 List 1

September 12, 2003

55

5

Once the test is complete, do one of the following:

If the system is to loopdown but remain armed, send the IR (Intelligent Repeater) LPDN code (universal
loopdown).

If all the equipment is to be looped down, disarmed and returned to normal operation, send the disarm
inband code 11100 or the ESF-DL code (FF24).

The Time-Out Override function is only valid for the current active loopback. The automatic
time-out timer is restored during subsequent loopback sessions.

The Armed mode has an automatic time-out of 120 minutes, but this timer is reset to 120 for any
of the following events:

Loopback terminates (manually or time-out)

Query

Alternate query

Far End activate

Another ARM command

This timer is inhibited while any of the valid command codes are being sent. Once the codes
are removed, the timer restarts at 120.