ADC HDSL4 User Manual
Page 14
Front Panel
LTPH-UM-1031-03, Issue 3
6
September 12, 2003
H4TU-C-319 List 1
LOOPBACK MESSAGES
CDU1
Customer Doubler 1 Loopback
DS1 signal from customer is looped back to the customer at H4D1
(111100).
CDU2
Customer Doubler 2 Loopback
DS1 signal from customer is looped back to the customer at H4D2
(111110).
CLOC
Customer Local Loopback
DS1 signal from customer is looped back to the customer at the H4TU-R.
COLB
Central Office Loopback
Dual loopback at the H4TU-C.
CREM
Customer Remote Loopback
DS1 signal from customer is looped back to the customer at the
H4TU-C.
NDU1
Network Doubler 1 Loopback
Signal is looped back to the network at H4D1 (110000).
NDU2
Network Doubler 2 Loopback
Signal is looped back to the network at H4D2 (111000).
NLOC
Network Local Loopback
DSX-1 signal is looped back to the network at the H4TU-C.
NREM
Network Remote Loopback
DSX-1 signal is looped back to the network at the H4TU-R.
RULB
Remote Unit Loopback
Dual loopback at the H4TU-R.
SMJK
Remote SmartJack Loopback
DSX-1 signal is looped back to the network at the H4TU-R SmartJack
module.
DIAGNOSTIC MESSAGES
A=xx
Maximum Loop Attenuation
The Attenuation (A) message appears followed by xx, where xx is the
highest loop attenuation of all HDSL interfaces.
ACQ1 or ACQ2
Acquisition 1 or Acquisition 2
The multiplexers of the H4TU-C and H4TU-R are trying to establish
synchronization over HDSL4 Loop 1 or Loop 2.
ARM
System Armed
Armed to respond to Intelligent Repeater Loop (ILR) codes.
BAD RT?
No Response from H4TU-R
The H4TU-C receives no response from the H4TU-R, and all HDSL4
loop conditions are normal; therefore, the integrity of the H4TU-R or
the HDSL4 loops is questionable.
FERR
Framing Bit Error Occurred
Framing bit error occurred at H4TU-C DSX-1 input.
HxES
HDSL4 CRC Error Loop 1 or Loop 2
H4TU-C HDSL4 Loop 1 or Loop 2 Cyclical Redundancy Check (CRC)
error. (Loop 1 has display priority over Loop 2.)
LBPV
Local Bipolar Violation
A bipolar violation has been received at the DSX-1 input to the
H4TU-C-319.
1=xx or 2=xx
HDSL4 Loop Margin
Indicates the power of the received HDSL4 signal on each loop relative
to noise (S/N with respect to 21.5 dB). Any value of 6 dB or greater is
adequate for reliable system operation. (xx denotes lowest margin in
dB for Loop 1 and Loop 2.)
MNGD
Managed
The H4TU-C-319 is under control of the HMU-319 network
management unit. In this state, the front-panel craft port and
pushbuttons are disabled.
PWR FEED OFF
Power Feed Off
HDSL4 span power has been turned off by setting the PWRF option to
OFF, or HDSL4 span power has been turned off by use of the A5LB
Intelligent Office Repeater (IOR) powerdown code.
PWR FEED ON
Power Feed On
Indicates that the HDSL4 loop power is applied and neither pair is
grounded.
SIG1 or SIG2
Signaling
The transceivers of the H4TU-C and H4TU-R are trying to establish
contact with each other over HDSL4 on Loop 1 or Loop 2.
SYSTEM INFORMATION MESSAGES
(a)
VER x.xx
Software Version Number
The software version number of the H4TU-C-319.
LIST xx
List Number
The list number of the H4TU-C-319.
Continued
Table 2.
Front-Panel Display Messages (Continued)
Message
Full Name
Description