Configuring the system, Config menu – ADC HDSL4 User Manual
Page 25
LTPH-UM-1031-03, Issue 3
Provisioning
H4TU-C-319 List 1
September 12, 2003
17
Configuring the System
The Config menu (
) allows you to make the following types of system configuration changes:
•
Standard options (
)
•
ADC options (
•
BERT Generator (
•
Date and time (see
“Setting Date and Time” on page 15
•
Master clear (see
“Clearing the History, Alarm, and Event Log Screens” on page 24
•
Reset to factory default configuration (
Figure 6.
Config Menu
Making Changes to Standard and ADC Options
show the Standard and ADC configuration options. Standard options are
supported by HDSL4 units when connected to units from other vendors. ADC options are an extended set of
options available only when using ADC units exclusively. For a description of each option and a list of possible
option settings, refer to
. To make changes to these options:
1
Press
to select the Config menu.
2
Use the
and
arrow keys to select Standard Options or ADC Options, then press
.
3
Use the arrow keys to select an option.
4
Press the
to cycle through the available settings for that option.
5
Press
to activate your choice.
The message
May need to change MUX option after changing this option
appears when changing the DS1 Line Coding (DS1) or H4TU-C Equalization (EQL) option in the
Standard Options configuration screen. (This applies when the H4TU-C is used in a
Wideband 3190 which contains a multiplexer.)
Monitor Performance Event Log
Config
Inventory Report Rlogon Help
+----------------------+
|
Standard Options ->
|
| ADC Options -> |
| BERT Generator -> |
| Date and Time -> |
| Master Clear |
| Set Factory Defaults |
+----------------------+
ID: xxxx--xxxx—-xxxx--xxxx 02/01/2002 12:30:01 H4TU-C System: OK