ADC HDSL4 User Manual
Page 28
Provisioning
LTPH-UM-1031-03, Issue 3
20
September 12, 2003
H4TU-C-319 List 1
H4TU-R TLOS
Loopback
TLOS
ENA
Enables a logic loopback at the H4TU-R when an LOS occurs at its DS1 input.
For priority resolution, see
.
DIS
Disables TLOS logic loopback.
Network Loopback
Pattern
NLBP
AIS
Enables the H4TU-R to transmit AIS towards the CI for any network loopback.
For priority resolution, see
.
LOS
Enables the H4TU-R to transmit LOS towards the CI for any network
loopback.
Power Back Off -
Network
See
(PBON and PBOC)
Options” on page 22
.
PBON
DEF
Configures the power output levels of the H4TU-C network unit toward the
customer to comply with the Default template as defined in Section 6.1.4.2 of
ANSI T1.418.
ENH
Configures the power output levels of the H4TU-C network unit toward the
customer to comply with the Enhanced template as defined in Section 6.1.4.2
of ANSI T1.418.
Power Back Off -
Customer
See
(PBON and PBOC)
Options” on page 22
.
PBOC
DEF
Configures the power output levels of the H4TU-R customer unit toward the
network to comply with the Default template as defined in Section 6.1.4.2 of
ANSI T1.418.
ENH
Configures the power output levels of the H4TU-R customer unit toward the
network to comply with the Enhanced template as defined in Section 6.1.4.2
of ANSI T1.418.
Table 6.
H4TU-C-319 List 1 ADC Config Menu Options
ADC Config Menu
Options
Screen
Display Code
Selection
Description
Line Power Feed
PWRF
OFF
Disables powering to the HDSL4 pair.
LOW
Keeps the HDSL4 line voltage at nominal -185 Vdc.
HIGH
Keeps the HDSL4 line voltage at nominal ±123 Vdc.
AUTO
Keeps the H4TU-C line voltage at -185 Vdc when line powering up to two
devices (one doubler and one remote unit, or two doubler units). When line
powering of more than two devices is required, the line unit automatically
switches to ±123 Vdc.
Remote Provisioning RTPV
ENA
Enables remote provisioning.
DIS
Disables remote provisioning.
Bipolar Violation
Transparency
See
Violation
Transparency
(BPVT) Option” on
page 22
BPVT
ENA
Enables BPVs and HDSL4 CRC errors at the DS1 input to be converted into
DS1 BPVs at the DS1 output at the distant end. This makes HDSL4
transparent to BPVs.
DIS
Disables BPV Transparency.
DS1 BER Threshold
See
Rate (DBER) Option”
on page 22
.
DBER
ENA
Enables the fixed 24-hour DS1 BER threshold.
DIS
Prevents the generation of a system alarm due to DS1 BER.
Continued
Table 5.
H4TU-C-319 List 1 Standard Config Menu Options (Continued)
Standard Config
Menu Options
Screen
Display Code
Selection
Description