beautypg.com

Table 5 on, Ected parameter. (see – ADC HDSL4 User Manual

Page 27

background image

LTPH-UM-1031-03, Issue 3

Provisioning

H4TU-C-319 List 1

September 12, 2003

19

Table 5

describes the Standard Config menu options and lists their menu screen display codes.

Table 6 on page 20

describes the ADC Config menu options. Selections in bold type are the factory default settings.

Table 5.

H4TU-C-319 List 1 Standard Config Menu Options

Standard Config
Menu Options

Screen
Display Code

Selection

Description

Loopback Timeout

LBTO

NONE

Disables automatic time-out cancellation of all loopbacks.

20 min

Sets automatic cancellation of all loopbacks to 20 minutes after initiation.

60 min

Sets automatic cancellation of all loopbacks to 60 minutes after initiation.

120 min

Sets automatic cancellation of all loopbacks to 120 minutes after initiation.

8 hr

Sets automatic cancellation of all loopbacks to 8 hours after initiation.

24 hr

Sets automatic cancellation of all loopbacks to 24 hours after initiation.

Loop Attenuation
Threshold

LATT

0 through
50 dB

Determines the maximum loop attenuation before an alarm is declared. Zero
disables the alarm. The loop attenuation threshold cannot be set from the
front-panel pushbuttons.

38 dB

Default value.

Margin Threshold

MARG

0 to 15 dB

Determines the minimum allowable margin below which a system alarm can
occur. Zero disables the alarm. The Margin (Alarm) threshold cannot be set
from the front-panel pushbuttons.

4 dB

Default value.

DS1 Frame
Formatting

FRMG

AUTO

Configures the HDSL4 system to operate in an auto-framing (AUTO) mode. It
detects and locks to both SF or ESF DS1 frame patterns. Line and path
performance parameters are maintained and displayed. Unframed payloads
cause the ES-P and SES-P counters to increment.

SF

Configures the HDSL4 system to search for the SF framing pattern at its DS1
input.

ESF

Configures the HDSL4 system to search for the ESF framing pattern at its DS1
input.

UNFR

Configures the same as AUTO except unframed payloads do not cause the
ES-P and SES-P counters to increment.

DS1 Line Coding

See

“DS1 Line

Coding (DS1)
Option” on page 21

.

DS1

AUTO

The H4TU-C and H4TU-R monitor the incoming DS1 bit streams for the B8ZS
code. If the H4TU-R detects this code, the H4TU-C enters B8ZS output mode.
The H4TU-C reverts back to AMI output mode if no B8ZS codes are received
at the H4TU-R input for 5 seconds. Similarly, when the H4TU-C detects the
B8ZS code, the H4TU-R enters the B8ZS mode and returns to AMI mode if no
B8ZS code is received at the H4TU-C input for 5 seconds.

B8ZS

Places both the H4TU-C and H4TU-R into their B8ZS modes.

AMI

Places both the H4TU-C and H4TU-R into their AMI modes.

H4TU-C Equalization EQL

0 ft

Sets the Equalizer to DSX-1 for 0 to 132 feet.

See

“H4TU-C

Equalization (EQL)
Option.” on page 21

.

133 ft

Sets the Equalizer to DSX-1 for 133 to 265 feet.

266 ft

Sets the Equalizer to DSX-1 for 266 to 398 feet.

399 ft

Sets the Equalizer to DSX-1 for 399 to 532 feet.

533 ft

Sets the Equalizer to DSX-1 for 533 to 655 feet.

H4TU-R Line
Buildout

RLBO

Sets the DS1 receive level output toward the Customer Interface (CI). Line
buildout can only be set through the maintenance screens.

0 dB

Sets the DS1 RLBO level toward the CI to 0 dB.

-7.5 dB

Sets the DS1 RLBO level toward the CI to -7.5 dB.

-15 dB

Sets the DS1 RLBO level toward the CI to -15.0 dB.

Alarm Pattern

See

“Alarm Pattern

(ALMP) Option.” on
page 22

.

ALMP

AIS

Enables the HDSL4 system to output an AIS payload at its DS1 ports for
LOSW and LOS DS1. For priority resolution, see

Figure 27 on page 45

.

LOS

Enables the HDSL4 system to output an LOS condition at its DS1 ports for
LOSW and LOS DS1.

Continued