Monitoring System Activity and Performance

H4TU-C-319 List 1

September 12, 2003

25

M

ONITORING

S

YSTEM

A

CTIVITY

AND

P

ERFORMANCE

The HDSL4 system provides the following maintenance screens for monitoring system activity and assessing
performance.

The Monitor screens provide a graphical representation of circuit activity and allow initiation of loopbacks.

The Performance screens provide current, 25-hour, 48-hour, and 31-day performance histories and a
continuous alarm history.

The Event Log provides a description of the 100 most recent events which include their origin, time and date
of occurrence, and message.

S

YSTEM

O

VERVIEW

The H4TU-C-319 List 1 supports up to two doublers with three HDSL4 spans as shown in

Figure 11

.

Figure 11.

System Spans

The Monitor and Performance screens provide important activity and performance information about the HDSL4
spans and span devices.

U

SING

THE

M

ONITOR

S

CREEN

TO

V

IEW

S

YSTEM

A

CTIVITY

1

Press

to view the system diagram.

Figure 12 on page 26

shows an armed circuit with an active loopback and alarms. Terms used on the system

diagram are defined in the onscreen Help menu glossary. Abnormal situations are highlighted on the diagram.
See

Table 8 on page 26

for screen field descriptions.

H4D1

H4D2

H4TU-R

H4TU-C

Span 1

Span 2

Span 3

Span 1

Span 1

Span 2

2 Doublers

1 Doubler

No Doubler

Central Office

M

This manual is related to the following products: