beautypg.com

Loopback test procedures, General troubleshooting tips, Oopback – ADC HDSL4 User Manual

Page 57: Rocedures

background image

LTPH-UM-1031-03, Issue 3

Testing

H4TU-C-319 List 1

September 12, 2003

49

CDx? = Doubler 1 or Doubler 2, if H4D is available

CLO? = CLOC

COL? = Dual loopback at H4TU-C

DxL? = Dual loopback at Doubler 1 or Doubler 2, if available

RUL? = Dual loopback at H4TU-R

4

Press SEL to activate the selected loopback. The previous loopback is terminated.

Once a loopback is selected and activated, the loopback stays active until it times out (based on the LBTO setting).
When a loopback times out, the display returns to the normal display mode.

You can terminate loopbacks manually and exit the

MAN LPBK

mode by simultaneously pressing the MODE and

SEL pushbuttons for 3 or more seconds. If no loopback is active, the

MAN LPBK

mode automatically terminates

after 30 seconds.

All loopbacks can be initiated by inband commands in the DS1 payload or by a command from the HDSL4 system
(front-panel pushbuttons or maintenance screen selections). Therefore, whenever a loopback is active, the method
by which it was activated is indicated in the loopback and status information (Monitor screen) by the annotation
HG or PL adjacent to the identified loopback. For example, NREM-HG indicates that the loopback was initiated
by the HDSL4 system.

L

OOPBACK

T

EST

P

ROCEDURES

The following sections provide step-by-step test procedures for verifying the integrity of the HDSL4 channels at
every module location as well as the DS1 channels to the customer and the local DSX-1 interface.

Figure 29 on

page 50

summarizes the available loopbacks in the system.

General Troubleshooting Tips

If trouble is encountered on the DSX-1 interface of the H4TU-C, verify that the:

H4TU-C is making a positive connection with its shelf connector.

H4TU-C internal equalizer is set to the correct distance range per

Table 5 on page 19

. All equalizers should

be set to the distance from the DSX-1 to the shelf.

The transmit and receive DSX-1 ports have splitting access jacks and miniature, 210-series, bridging jacks as
shown in

Figure 1 on page 3

. Connecting one cable between the two (BRG) jacks and another between the two

LINE jacks splits the IN and OUT and creates metallic loopbacks towards both the DSX-1 and the H4TU-C-319.
If separate plugs are inserted into both LINE jacks with the other end disconnected, the BRG jacks can be used to
send and receive test patterns towards the DSX-1.

SMJK loopback commands are only activated by inband commands.

This manual is related to the following products: