beautypg.com

Maximum current drain, Loop attenuation, insertion loss, and reach, Hdsl4 reach chart – ADC HDSL4 User Manual

Page 69: Maximum, Rs in, The data in, Table 21

background image

LTPH-UM-1031-03, Issue 3

Appendix A - Specifications

H4TU-C-319 List 1

September 12, 2003

61

M

AXIMUM

C

URRENT

D

RAIN

The maximum current drain is the maximum current drawn from the shelf power supply when it is at its minimum
voltage (-42.5

Vdc

). This determines the shelf fusing requirements. Use the -42.5 Vdc current data in

Table 21

to

determine the shelf fusing requirements for your particular H4TU-C applications.

L

OOP

A

TTENUATION

, I

NSERTION

L

OSS

,

AND

R

EACH

For Span 1, each loop has no more than 47 dB of insertion loss at 196 kHz, with driving and terminating
impedances of 135

Ω, as shown in

Table 21

below. This is equivalent to no more than 34 dB loop attenuation.

For Span 2 and Span 3, each loop has no more than 43 dB of insertion loss at 196 kHz, with driving and
terminating impedances of 135

Ω. This is equivalent to no more than 31 dB loop attenuation.

Table 21.

HDSL4 Reach Chart

Cable Gauge

Insertion Loss

(a)

at

196 kHz (dB/kft)

(a) Insertion Loss = 1.38 times loop attenuation

Loop Attenuation

(dB/kft)

Maximum Reach (kft)

Span 1

Maximum Reach (kft)

Span 2 and Span 3

per kft

26/0.4 mm

3.88

2.8

12

11.0

83

24/0.51 mm

2.84

2.0

16

15.0

52

22/0.61 mm

2.18

1.6

21

20.6

32

19/0.91 mm

1.54

1.1

29

27.8

16

This manual is related to the following products: