beautypg.com

Airflow light – Alliance Laundry Systems T433I User Manual

Page 52

background image

Adjustments

M414038

50

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Airflow Light

Manual Timer Models Only

The light on the front control indicates when the
airflow through the tumbler is less than normal. When
this light flickers on and off or stays on all the time,
the tumbler cannot operate properly.

If cleaning the lint screen does not correct the
problem, other possibilities include: Lint build-up in
the exhaust line or discharge vent, incorrect rotation of
blower, lack of make-up air, jammed backdraft
damper, overloaded tumbler or anything else that will
reduce the airflow.

Figure 21

The airflow light is wired to the normally close contact
of the airflow switch, so when the airflow switch
flutters or does not pull in, the light will advise the
operator that there is a problem, which should be
corrected immediately. It is normal for the light to
come on for two seconds when the tumbler is started.
It should go out when the blower is up to speed.

Figure 22

T173I

1

Airflow Switch (Non-EU)

2

Airflow Switch (EU)

3

Final Drive Eyebolt

4

Reversing Motor 3/4 Horsepower

5

Drive Motor Eyebolt

6

Blower Motor 1 Horsepower

2

3

4

5

1

6

FOR 120 POUND TUMBLERS ONLY

T283I

1

Airflow Switch

2

Final Drive Eyebolt

3

Reversing Motor 3/4 Horsepower

4

Drive Motor Eyebolt

5

Blower Motor 3 Horsepower

T283i

1

FOR 170 POUND TUMBLERS ONLY

2

3

4

5