Installation 27, Table 3 – Alliance Laundry Systems T433I User Manual
Page 29
Installation
27
M414038
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Model 170FG
Input: 115.8 kW
Flue Code: B
22
Table 3
NOTE: In addition to directions below, follow all
instructions including verification and adjustment
of injector pressure.
1 – Order as Regulated Natural Gas. No modification
needed.
2 – Order as Regulated Natural Gas. Apply
appropriate country sticker.
3 – Order as Regulated Natural Gas. Apply
appropriate country and gas stickers.
4 – Order as Unregulated with Unregulated Natural
Gas injectors. Apply appropriate country sticker.
5 – Order as Unregulated with L.P. Gas injectors.
Apply appropriate country sticker.
6 – Order as Regulated Natural Gas. Convert with
(3) 3.4 mm injectors Part No. M400997. Apply
appropriate country and gas stickers.
7 – Order as Unregulated with L.P. Gas. No
modification needed.
8 – Order as Unregulated with L.P. Gas. Apply
appropriate country sticker.
OPEN – No Approval available.
Special Cases – When converting from Natural Gas to
L.P. Gas, the left-most burner and injector (viewed
from front) must be removed. In the place of the
removed injector, a blank injector Part Number
M400995 and a Burner Opening Cover Part Number
M413099 must be installed. No additional kits are
required to convert from regulated to unregulated.
Gas
Type
GB
IE
PT
ES
IT
DK
NO
SE
FI
DE
NL
BE
FR
AT
Gas
Family
& Group
Inject. 0
Inject. Qty
& Part. No.
Inlet
Press.
Gvnr./
Regltr.
Inject.
Press.
Nat.
Gas
1
1
1
1
1
2
2
2
2
2
2
2nd
family
Group H
(E)
4.8 mm
4
M411372
20 mbar
Yes
8.0 mbar
3
2nd
family
Group L
(LL)
4.8 mm
4
M411372
25 mbar
Yes
12.0
mbar
4
4
2nd
family
Group E+
3.8 mm
4
M402997
20.25
mbar
No
Unreg.
L.P.
Gas
5
5
5
5
5
5
3rd
family
Group
B/P
3.4 mm
3
M400997
30 mbar
No
Unreg.
6
6
3rd
family
Group
B/P
3.4 mm
3
M400997
50 mbar
Yes
28.7
mbar
7
7
7
7
7
8
8
3rd
family
Group 3+
3.4 mm
3
M400997
28.37
mbar
No
Unreg.