Installation

M414038

22

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Basic Configuration

1. Determine the necessary conversion operations

to convert from the factory-supplied
configuration to the desired configuration.

2. Perform the conversions required so the machine

is properly configured for the desired country and
gas (refer to Specific Conversion Procedures
Section):

How to Convert Gas Valve from Regulated to
Unregulated

NOTE: Conversion from regulated to unregulated
is only needed when regulated tumblers were
ordered, but unregulated tumblers were needed.

How to Change Injector (Orifice) Size

How to Adjust Gas Valve Governor/Regulator

3. If applicable, peel off the appropriate country

sticker from Part No. 503382 (included with
machine) and apply it to the serial plate over the
existing country information. Refer to Figure 7.

4. If applicable, peel off the appropriate conversion

sticker from Part No. M413800 (included with
machine) and apply it to the serial plate over the
“ADJUSTED FOR ______ GAS: ______”
information. Refer to Figure 7.

Figure 2

WARNING

When converting the tumbler to a
different gas or pressure, first verify that
the supply inlet pressure is equipped with
a pressure regulator (located ahead of the
tumbler) that will maintain the gas supply
at the inlet pressure specified.

W430

T103K

1

Gas Shut-Off Valve (Ahead of pressure tap)

2

Pressure Tap

3

Gas Shut-Off Valve (Shown in closed
position)

SPECIFIED

LOCAL INLET

PRESSURE

3

2

1