beautypg.com

Instant electronic ignition system – Alliance Laundry Systems T433I User Manual

Page 42

background image

Gas Requirements

M414038

40

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Instant Electronic Ignition System

To light and shut down Instant Electronic Ignition
system:

1. Remove access panel.

2. Turn gas shut-off valve to open position

(handle should be parallel with the gas line).
Refer to Figure 15.

3. Replace access panel.

4. Start tumbler in drying cycle. Spark igniter will

begin high intensity sparking as the gas valve
simultaneously opens. The gas burner(s) are
ignited by the sparking igniter. Igniter will shut
off, and burner(s) will remain on as long as the
temperature control calls for heat.

5. Opening the tumbler door will cause flame to

extinguish. Closing door and starting tumbler
will restart ignition cycle.

IMPORTANT: The Instant Electronic Ignition
system will attempt to light the gas by sparking for
approximately 15 seconds. If gas ignition does not
take place within 15 seconds the Instant Electronic
Ignition control will go into safety lockout and the
valve will no longer open until the Instant
Electronic Ignition control is reset. To reset Instant
Electronic Ignition control, remove power from
control by opening and closing the loading door. If
condition persists, check that the gas shut-off valve
is in open position and that the gas service is
properly connected. If condition still persists,
remove tumbler from service.

6. To remove tumbler from service, disconnect

electrical service, and turn gas shut-off valve to
closed position (handle should be at right angle to
the gas line).

Figure 15

T087K

1

Closed Position

5

Burner Support Bracket

2

Open Position

6

Spud Holder

3

Gas Shut-Off Valve

7

Union Nut

4

Manometer

T087K

1

2

3

4

6

5

7