beautypg.com

Installation, Table 2 – Alliance Laundry Systems T433I User Manual

Page 28

background image

Installation

M414038

26

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Model 120FG

INPUT: 87.8 kW

Table 2

NOTE: In addition to directions below, follow all
instructions including verification and adjustment
of injector pressure.

1 – Order as Regulated Natural Gas. No modification
needed.

2 – Order as Regulated Natural Gas. Apply
appropriate country sticker.

3 – Order as Regulated Natural Gas. Apply
appropriate country and gas stickers.

4 – Order as Unregulated with Unregulated Natural
Gas injectors. Apply appropriate country sticker.

5 – Order as Unregulated with L.P. Gas injectors.
Apply appropriate country sticker.

6 – Order as Regulated Natural Gas. Convert with
(3) 2.6 mm injectors Part No. M411376. Apply
appropriate country and gas stickers.

7 Order as Unregulated with L.P. Gas injectors. No
modification needed.

8 – Order as Unregulated with L.P. Gas injectors.
Apply appropriate country sticker.

OPEN – No Approval available.

Special Cases No additional kits are required to
convert from regulated to unregulated.

Gas

Type

GB

IE

PT

ES

IT

DK

NO

SE

FI

DE

NL

BE

FR

AT

Gas

Family

& Group

Inject. 0

Inject. Qty

& Part. No.

Inlet

Press.

Gvnr./

Regltr.

Inject.

Press.

Nat.

Gas

1

1

1

1

1

2

2

2

2

2

2

2nd

family

Group H

(E)

4.8 mm

3

M411372

20 mbar

Yes

8.9 mbar

3

2nd

family

Group L

(LL)

4.8 mm

3

M411372

25 mbar

Yes

12.0

mbar

4

4

2nd

family

Group E+

4.2 mm

3

M402295

20.25

mbar

No

Unreg.

L.P.
Gas

5

5

5

5

5

5

3rd

family
Group

B/P

2.6 mm

3

M411376

30 mbar

No

Unreg.

6

6

3rd

family
Group

B/P

2.6 mm

3

M411376

50 mbar

Yes

26.4

mbar

7

7

7

7

7

8

8

3rd

family

Group 3+

2.6 mm

3

M411376

28.37

mbar

No

Unreg.