Corascript_onserverconnectstarted(), Name, Description – Campbell Scientific LoggerNet-SDK Software Development Kit User Manual
Page 75: Corascript_onserverconnectfailure()

Section 15. CsiCoraScript Control Reference
CoraScript_onServerConnectStarted()
Name
onServerConnectStarted()
Description
The control has connected to the LoggerNet server.
CoraScript_onServerConnectFailure()
Name
onServerConnectFailure(server_failure_type
server_failure)
Description
An error has occurred that caused the connection to the LoggerNet server to
fail for this control.
Table of Possible failure codes.
Enumeration Name
Value Description
server_failure_unknown
0
Indicates that an error has occurred
but its nature is unknown
server_failure_logon
1
Indicates that this control was unable
to logon to the LoggerNet server
because either the logonName or
logonPassword property is incorrect
server_failure_session
2
Indicates that the communication
session with the LoggerNet server
failed resulting in a failed transaction
server_failure_unsupported
3
The version of the LoggerNet server
does not support this transaction
server_failure_security 4
Indicates that the account specified
by logonName does not have
sufficient privileges to start this
transaction with the LoggerNet
server
server_failure_bad_host_or_port 5
Indicates that either the serverName
or the serverPort property is
incorrect
15-5