Com return values, Advisor.stop(), Name – Campbell Scientific LoggerNet-SDK Software Development Kit User Manual
Page 144: Description, Advisor.variablesetcancel(), Parameter
Section 18. CsiDataSource Control Reference
COM Return Values
Table of Possible Values
Code Meaning
S_OK
Success: Normal return
E_CSI_ALREADY_CONNECTED Error: This advisor has already been
started
E_FAIL
Error: An unexpected error has
occurred
Advisor.stop()
Name
Advisor.stop()
Description
This method will stop the advisor from monitoring the LoggerNet data cache
for transactions. When an advisor is stopped, its properties can be modified.
COM Return Values
Table of Possible Values
Code Meaning
S_OK
Success: Normal return.
Advisor.variableSetCancel()
Name
Advisor.variableSetCancel(Long tran_id)
Description
This method attempts to cancel a variableSetStart() transaction. The event
onVariableSetComplete() will notify you if the cancellation was successful.
This method should only be called when the state of advisorStarted is TRUE.
Parameter
tran_id: The unique transaction ID given by variableSetStart()
COM Return Values
Table of Possible Values
Code Meaning
S_OK
Success: Normal return
18-20