Datalogger_onprogramsent(), Name, Description – Campbell Scientific LoggerNet-SDK Software Development Kit User Manual
Page 121: Com return values, Datalogger_onselectivemanualpollcomplete(), Parameters

Section 17. CsiDatalogger Control Reference
Datalogger_onProgramSent()
Name
onProgramSent()
Description
This event returns notification when the program has been sent but gets called
before the program has been compiled on the datalogger and table definitions
have been retrieved.
COM Return Values
Table of Possible Values
Code Meaning
S_OK
Success: Normal return
Datalogger_onSelectiveManualPollComplete()
Name
onSelectiveManualPollComplete(Boolean successful,
selective_manual_poll_outcome_type response_code)
Description
The response from the LoggerNet server when the selective manual poll
completes
Parameters
Table of response_code values
Enumeration Name
Value
Description
smp_outcome_unknown
0
Indicates that an unknown error as occurred
smp_outcome_success
1
Indicates that the selective manual poll was
successful
smp_outcome_invalid_logon
2
Indicates that this control was unable to logon
to the LoggerNet server because either the
serverLogonName or serverLogonPassword
property is incorrect
smp_outcome_server_session_failed
3
Indicates that the communication session with
the server failed causing the selective manual
poll transaction to fail
smp_outcome_invalid_device_name
4
Indicates that the datalogger device
“loggerName” was not found in the broker
map
smp_outcome_unsupported
5
Indicates that the device does not support the
selective manual poll process
17-23