Com return values, 2 methods, Datalogger.clockcancel() – Campbell Scientific LoggerNet-SDK Software Development Kit User Manual
Page 104: Name, Description, Datalogger.clockcheckstart()

Section 17. CsiDatalogger Control Reference
COM Return Values
Table of Possible Values
Code Meaning
S_OK
Success: Normal return
E_CSI_INVALIDARG Error: The port value is invalid
E_CSI_BUSY
Error: Attempt to set serverPort while connected
to the LoggerNet server
17.1.2 Methods
Datalogger.clockCancel()
Name
Datalogger.clockCancel()
Description
This method should be called to cancel either a clockCheckStart(), or a
clockSetStart(). If the clock set or clock check was successfully cancelled,
then the event onClockComplete(), will return a cancellation code. If the
clockCancel() was called too late in the process, then the event
onClockComplete(), will return either a success or failure code instead. This
method should only be called when the clockCheckStart() method or the
clockSetStart() method is in process.
COM Return Values
Table of Possible Values
Code Meaning
S_OK
Success: Normal return
Datalogger.clockCheckStart()
Name
Datalogger.clockCheckStart()
Description
This method should be called to check the date and time on a specified
datalogger. This method should only be called when the value of
serverConnected, is true. If not, this method will return
E_CSI_NOT_CONNECTED
. Upon completion, this method will fire the event
17-6