Section 15. csicorascript control reference, 1 corascript interface, 1 properties – Campbell Scientific LoggerNet-SDK Software Development Kit User Manual
Page 71: Corascript.serverconnected, Name, Description, Com return values, Corascript.serverlogonname, Valid values, Default value
Section 15. CsiCoraScript Control
Reference
15.1 CoraScript Interface
15.1.1 Properties
CoraScript.serverConnected
Name
CoraScript.serverConnected As Boolean (read-only)
Description
This Boolean property describes the state of the connection between the
CoraScript control and the LoggerNet server. The property returns TRUE if
the connection exists. Otherwise, the property returns FALSE.
COM Return Values
Table of Possible Values
Code Meaning
S_OK
Success: Normal return
CoraScript.serverLogonName
Name
CoraScript.serverLogonName As String
Valid Values
If security is enabled on the target LoggerNet server, this string must be one of
the account names recognized by the LoggerNet server.
Default Value
The default value for this property is an empty string. This property will only
affect the operation of the control if security is enabled on the LoggerNet
server.
COM Return Values
Table of Possible Values
Code Meaning
S_OK
Success: Normal return
E_CSI_BUSY
Error: The property cannot be set while a connection to
the LoggerNet server is present
15-1