Corascript.serverlogonpassword, Name, Valid values – Campbell Scientific LoggerNet-SDK Software Development Kit User Manual
Page 72: Default value, Com return values, Corascript.servername, Description

Section 15. CsiCoraScript Control Reference
CoraScript.serverLogonPassword
Name
CoraScript.serverLogonPassword As String
Valid Values
If security is enabled on the target LoggerNet server, this string must be the
password associated with the account named by CoraScript.serverLogonName.
Default Value
The default value for this property is an empty string. This property will only
affect the operation of the control if security is enabled on the LoggerNet
server.
COM Return Values
Table of Possible Values
Code Meaning
S_OK
Success: Normal return
E_CSI_BUSY Error: The property cannot be set while a connection to the
LoggerNet server is present
CoraScript.serverName
Name
CoraScript.serverName As String
Description
Specifies the TCP/IP interface address for the computer hosting the LoggerNet
server. This string must be formatted either as a qualified Internet machine
domain name or as an Internet address string. An example of a valid machine
domain name address is
www.campbellsci.com
. An example of a valid
Internet address string is
63.255.173.183
.
The default value for this property is the string
localhost
.
COM Return Values
Table of Possible Values
Code Meaning
S_OK
Success: Normal return
E_CSI_BUSY Error: Attempt to set serverName while connected to the
LoggerNet server