Advisor.startintervalseconds, Name, Description – Campbell Scientific LoggerNet-SDK Software Development Kit User Manual
Page 138: Valid values, Default value, Notes, Com return values, Advisor.startoption, E startoption

Section 18. CsiDataSource Control Reference
Advisor.startIntervalSeconds
Name
Advisor.startIntervalSeconds As Long
Description
This property specifies the number of seconds back from the newest record in
the table to collect when the value of startOption is set to
csidsStartRelativeToNewest.
Valid Values
A valid value must either be zero or a positive integer.
Default Value
The default value for this property is 0 (meaning select the newest record).
Notes
This property can be read at any time but can only be set when the state of the
property is advisorStopped.
COM Return Values
Table of Possible Values
Code Meaning
S_OK
Success: Normal return
E_CSI_BUSY
Error: The Advisor is started and already accessing the
LoggerNet server data
Advisor.startOption
Name
Advisor.startOption As csidsStartOptionType
Description
This property specifies how to select the first record when retrieving collected
data from the LoggerNet server data cache.
Valid Values
This property must take on one of the following values:
18-14