Section 10. CsiDataSource Control
10.1 Purpose of the CsiDataSource Control
The CsiDataSource control allows an application to monitor data collected
through the LoggerNet server. These sessions that monitor data are know as
Advisors. Advisors display data collected in the LoggerNet server data cache.
This control can have multiple advisor sessions with a single server connection.
This control requires that the LoggerNet server collect data for the same tables
or final storage areas that are being monitored. If you start an advisor on a
table that is not being collected by the LoggerNet server, you will not receive
any onAdviseRecord events. An exception to this rule occurs if you are
monitoring input locations on a mixed-array datalogger. When you create an
advisor for an input location on a mixed-array datalogger, a temporary data
cache is created. Then, with the advisor ready, enabling scheduled collection
with the datalogger will return records to the advisor.
The CsiBrokerMap control is often used in conjunction with this control to
display what tables and columns can be monitored. Additionally, the
CsiDatalogger control can also be used to issue a manual data poll and collect
records from the datalogger.
10.2 Connecting to the Server
There are two basic actions required to connect to the LoggerNet server:
1. Set server properties:
• serverName - The name or IP address of the LoggerNet server. The
default value is
localhost
.
•
serverPort - The port on which the LoggerNet server is running. The
default value is
6789
• logonName (Optional) - If security has been enabled on the server, a
valid logon name is required.
• logonPassword (Optional) - If security has been enabled on the
server, the correct password for a valid logon name is required.
method.
10-1