TXT Text Transmission
These short text messages and their interpretation are shown in
Table 10
on page 120
.
The text transmission response format:
$WITXT,xx,xx,xx,c--c*hh
1. See Chapter 8, section Supervisor Message, Setting Fields for definitions
of the Heating voltage field.
Table 7
Transducer Table
Transducer
Type
Units Field
Comments
Temperature
C
C = Celsius
F = Fahrenheit
Angular displacement
(wind direction)
A
D = degrees
Wind speed
S
K = km/h, M = m/s, N =
knots
S = mph, non-
standardized
1
Pressure
P
B = bars, P = Pascal
H = hPa, I = inHg,
M = mmHg
Humidity
H
P = Percent
Accumulated
precipitation
V
M = mm, I = in, H = hits non-standardized1
Time (duration)
Z
S = seconds
non-standardized1
Intensity (flow rate)
R
M = mm/h, I = in/h, H =
hits/h for rainfall
M = hits/cm2h, I = hits/
in2h, H = hits/h for hails
non-standardized1
Voltage
U
V = volts (also 50 %
duty cycle for heating)
N = not in use, F = 50%
duty cycle for heating,
W = full power for
heating
1. Not specified in the NMEA 0183 Standard.
where
$
=
Start of the message
WI
=
Talker identifier (WI = weather instrument)
TXT
=
Text transmission identifier.
xx
=
Total number of messages, 01 to 99
xx
=
Message number.