Vaisala WXT510 User Manual
Page 107

Chapter 8 ____________________________________________ Sensor and Data Message Settings
VAISALA ______________________________________________________________________ 105
[S]
=
Units for surface hits:
M = metric (accumulated hailfall in hits/cm
2
, Hail
event duration in s, Hail intensity in hits/cm
2
h)
I = imperial (the corresponding parameters in units
hits/in
2
, s, hits/in
2
h), H = hits (hits, s, hits/h)
Changing the unit resets the precipitation counter.
[M]
=
Autosend mode: R = precipitation on/off, C = tipping
bucket, T = time based
R = precipitation on/off: The transmitter sends a
precipitation message 10 seconds after the first
recognition of precipitation. Rain duration Rd
increases in 10 s steps. Precipitation has ended when
Ri = 0. This mode is used for indication of the start
and the end of the precipitation.
C = tipping bucket: The transmitter sends a
precipitation message at each unit increment (0.1
mm/0.01 in). This simulates conventional tipping
bucket method.
T = time based: Transmitter sends a precipitation
message in the intervals defined in the [I] field.
However, in polled protocols the autosend mode
tipping bucket should not be used as in it the
resolution of the output is decreased (quantized to
tipping bucket tips).
[Z]
=
Counter reset: M = manual, A = automatic, Y =
immediate
Sets both rain/hail accumulation count and duration
of the rain/hail event to zero.
M = manual reset mode: The counter is reset with
aXZRU command only, see
Precipitation Counter
Reset (aXZRU) on page 54
.
A = automatic reset mode: The counts are reset after
each precipitation message whether in automatic
mode or when polled.
Y = immediate reset: The counts are reset
immediately after receiving the command.
=
Response terminator