Vaisala WXT510 User Manual
Page 62

User’s Guide ______________________________________________________________________
60 __________________________________________________________________ M210470EN-D
To change the parameters and units in the response message and to
make other sensor settings, see section
Wind Sensor on page 93
.
Pressure, Temperature and
Humidity Data Message (aR2)
With this command you can request a pressure, temperature and
humidity data message.
Command format: aR2
Example of the response (the parameter set is configurable):
0R2,Ta=23.6C,Ua=14.2P,Pa=1026.6H
To change the parameters and units in the response message and to
make other sensor settings, see section
Pressure, Temperature, and
Humidity Sensors on page 99
.
Sx
=
Wind speed maximum (M = m/s)
=
Response terminator
where
a
=
Device address
R2
=
Pressure, temperature and humidity message query
command
=
Command terminator
where
a
=
Device address
R2
=
Pressure, temperature and humidity query command
Ta
=
Air temperature (C = °C)
Ua
=
Relative humidity (P = % RH)
Pa
=
Air pressure (H = hPa)
=
Response terminator