Chapter 8 ____________________________________________ Sensor and Data Message Settings
VAISALA ______________________________________________________________________ 101
Changing the Settings
You can change the following settings:
-
parameters included in the data message,
-
update interval,
-
pressure unit, and
-
temperature unit.
Make the desired setting with the following command. Select the
correct value/letter for the setting fields, see
Setting Fields on page 100
.
See the examples.
Command format in ASCII and NMEA 0183:
aTU,R=x,I=x,P=x,T=x
Command format in SDI-12:
aXTU,R=x,I=x,P=x,T=x!
Examples (ASCII and NMEA 0183, device address 0):
You need the temperature and humidity data to be available in every 30
seconds
Changing the parameter selection:
0TU,R=0101000001010000
0TU,R=01010000&01010000
where
R, I, P, T
=
The pressure, temperature and humidity sensor
setting fields, see
Setting Fields on page 100
.
x
Value for the setting
=
Command terminator in ASCII and NMEA 0183
!
=
Command terminator in SDI-12
NOTE
Character '&' is not allowed in the command.