beautypg.com

Example: read co2 measurement result, Example: read co, Measurement result – Vaisala GMP231 User Manual

Page 62: Table 23, Get_parameter invoke message example, Table 24, Get_parameter response message example

background image

User's Guide _______________________________________________________________________

60 ___________________________________________________________________ M211501EN-C

Example: Read CO

2

Measurement Result

Table 23

Get_Parameter Invoke Message Example

Message Bytes (hex)

Content

12

I

2

C address

81

Get_parameter command

09

Device address

06

Frame length

0A

CO2 Parameter ID

AA

CRC high

9F

CRC lo


Table 24

Get_Parameter Response Message Example

Message Bytes (hex)

Content

13

I

2

C address

00

Status byte (no errors, ACK)

81

Get_parameter command

09

Device address

0B

Frame length

0A

CO2 Parameter ID

69

CO2 value 653.6314 ppm

68
23
44
75

CRC high

7D

CRC lo