beautypg.com

ページ31, Programming the boost stability, Gain – GReddy Profec User Manual

Page 32

background image

■Programming the Boost Stability■

GAIN

SET

SET

Adjust GAIN value to +

Adjust GAIN value to ‒

Boost

Time

Boost

Time

GAIN

Controls the boost curve tendency after the START pressure value. (stability and
consistency at higher RPMs)

・Program a boost level with the SET and START, before adjusting the GAIN.
・If the START pressure value is set to 0x100kPa or 0PSI, GAIN will not function.

Boost settings

(1) In a BOOST mode set up screen, highlight GAIN and
press the SET DIAL to confirm.

(3) To program the GAIN % value, press the SET DIAL to
confirm and return to the BOOST mode set up screen.

(2) Rotate the SET DIAL to change a GAIN % value.
* To cancel and return to the previous setting and the
BOOST mode set-up screen, press MODE.

Mode s set up screen

Mode s set up screen

To improve boost from dropping at higher RPM (boost fall
off), adjust the GAIN to a positive value. There may be
vehicles or turbocharger configurations which will not
allow for improvements.

Once the SET and START pressure values are adjusted to obtain the desired boost pressure, the GAIN can also be
used to drop boost pressure at higher RPMs by setting a negative value for the GAIN.

If the GAIN value is programmed too high, it may cause unstable boost, with a
fluctuating boost curve (boost creep).