START TYPE

Determines how the boost controller will function until the START BOOST value.

■Programming■

START TYPE

SET

SET UP

Boost

Time

0.7×100kPa

NORMAL

(limited control)

CONTROL

(Maximum control)

(1) In the main SET UP screen, rotate the SET DIAL to
highlight ST.TYPE. Then press the SET DIAL to confirm.

(2) Rotate the SET DIAL to highlight and select CONTROL or
NORMAL. Press the SET DIAL to confirm.
* To cancel and return to the previous setting and the
main SET UP screen, press MODE.

Configurations

CONTROL : START (BOOST) attempts to control the wastegate with the solenoid valve
for the entire boost range.
NORMAL: START (BOOST) only activates the boost control solenoid from the
programmed START (BOOST) value on.

Example:
If the START BOOST value is programmed at 0.7x100kPa, CONTROL will allow for
quicker boost response.