■Programming the Boost Pressure■

SET

SET

SET

SET

Changes the boost pressure by controlling the boost control solenoid valve.
This SET value in percentage (%) adjusts the boost control solenoid valve duty cycle,
it does not set an actual boost pressure value.

・As the SET % value is increased between 0-100%, it increases the boost level over

the turbocharger s base wastegate boost level.

・100% value will increase the boost level of the turbocharger systems maximum

capacity.

・0% value will be the base boost level turbocharger system (boost can not be set

below the base boost level).

(1) In a BOOST mode set up screen, highlight SET and
press the SET DIAL to confirm.

(3) To program the SET % value, press the SET DIAL to
confirm and return to the BOOST mode set up screen.

* Refer to page 38 for SET shortcuts.

(2) Rotate the SET DIAL to change a SET % value.
To cancel and return to the previous setting and the
BOOST mode set-up screen, press MODE.

Boost settings

Mode s set up screen

Mode s set up screen

Important

・There may be vehicles or turbocharger set-ups which are unable to reach

your target boost pressure.